Can these products be connected?
Manufacturer-listed pairing
ALLPOWERS lists SP027 as a compatible panel for the R600. The cited single-panel voltages and currents fit the documented input limits; use the matching solar-to-XT60 cable and confirm the labels on your units.
Basis: Official-document comparison; no physical test. Source 1 Source 2
Power-station input: ALLPOWERS R600
AP-SS-005-PRO; UK 299Wh listing; solar DC input only
| Parameter | Value | Condition / gap | Source |
|---|---|---|---|
| Solar input minimum | 12 V | Source 1 | |
| Solar input maximum | 60 V | Source 1 | |
| Documented input-current limit | 8.8 A | Source 1 | |
| Solar input power ceiling | 220 W | Source 1 | |
| Selected charging input | XT60 | Source 1 |
Solar-panel output: ALLPOWERS SP027
AP-SP-027; current UK listing
| Parameter | Value | Condition / gap | Source |
|---|---|---|---|
| Panel nameplate power | 100 W | Source 2 | |
| Open-circuit voltage (Voc) | 21.6 V | Source 2 | |
| Maximum-power / working voltage | 17.8 V | Source 2 | |
| Maximum-power / working current | 5.16 A | Source 2 | |
| Short-circuit current (Isc) | 6.17 A | Source 2 | |
| Panel output | MC4-style solar connector | Source 2 | |
| Voc temperature coefficient | Not established | Not provided in the cited specifications; cold-weather array sizing is not approved by this comparison. | Source 2 |
Conditions before connection
- The SP027 listing gives 100 W, 17.8 V and 5.16 A; these are retained as published. Their product is not used to replace the nameplate power, and the page advises checking the unit-specific manual.
- One unmodified panel only. This comparison does not approve series/parallel arrays or mixing panel revisions.
- Use the manufacturer-specified charging input and cable. Check connector keying, polarity and cable ratings against the actual equipment; a matching connector name alone is not approval.
- Do not connect a panel to an AC input or a DC output. Do not bypass protection or alter wiring to force a connection.
- Manufacturer-listed pairing is not a laboratory test by Factinery. Nameplate watts are not a promise of charging speed.
Not assessed here: Firmware compatibility; Extension battery compatibility; UPS performance; Recall clearance; Multi-panel array design.
Why these two model names matter
The R600 page identifies AP-SS-005-PRO. The SP027 source identifies AP-SP-027 and warns that specifications can vary between versions. Keep those identities with the comparison rather than treating every product sold as a 100W ALLPOWERS panel as interchangeable.
What the comparison establishes
The panel open-circuit value is below the station ceiling and its working voltage is inside the input window. Its documented working and short-circuit currents are also below the R600 published input limit. These checks support the manufacturer listing for one panel; they are not an approval of extra panels or a guarantee that charging will reach the nameplate wattage.
Cable and purchasing check
The panel uses solar connectors, while the station uses XT60. Confirm that the cable supplied with your particular bundle is the correct solar-to-XT60 cable. An Anderson adapter supplied with another kit is not the station input. Keep the panel version and cable part description together in the purchase record.
Compare the other documented power-station and panel combinations.
Sources and updates
Scope of this page: AP-SS-005-PRO; UK 299Wh listing; solar DC input only; AP-SP-027; current UK listing. One panel, selected input only.
R600 UK specifications and panel-compatibility FAQ
Original publication · ALLPOWERS
Specification table and solar-panel FAQ; AP-SS-005-PRO
Source accessed: 29 October 2026
SP027 UK product specification
Original publication · ALLPOWERS
AP-SP-027 specification table and version disclaimer
Source accessed: 29 October 2026
Update note: Model-specific solar-input comparison. Sources and unresolved conditions are identified below.
Content updated 29 October 2026. Source dates describe the documents or the recorded access to them.
How information is documented